The off-row data node at page (1:404350), slot 1, text ID 97654538240 is referenced by page (1:313911), slot 9, but was not seen in the scan.Msg 8978, Level 16, State 1, Line 1 Table error: Object ID 206623779, index ID 2, partition ID 72057594043629568, alloc unit ID 72057594045071360 (type In-row data).The last good backup is to old that I can restore from this backup.The off-row data node at page (1:398), slot 71, text ID 84760772804608 is not referenced.The off-row data node at page (1:404372), slot 1, text ID 97659125760 is not referenced.

Recovering orphaned file yukonuw.pck.Z (566) into directory file 564.First of all take the backup of your database and repair your indexes by an advanced.This must be something very simple for the JavaScript experts out there.Do you have a condition where the selected value will return a much large number of rows.

The file name index present bit in file 0x420 should not be set.Index node page (1:408538), slot 33 refers to child page (1:404141) and previous child (1:404140), but they were not encountered.Misses in library cache during parse: 1 Optimizer mode: CHOOSE Parsing user id: 79 (CISADM).The object id in file 0x2a does not appear in the object id index in file 0x24f5.

Page (1:2249) is missing a reference from previous page (1:2324).There are 133 rows in 1 pages for object sys.syssingleobjrefs.Msg 8909, Level 16, State 1, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID -1899679717971263488 (type Unknown), page ID (1:2240121) contains an incorrect page ID in its page header.Recovering orphaned file oemsetup.inf (525) into directory file 524.If it does, follow its instructions to enable Location Services for Safari.

Misses in library cache during parse: 1 Misses in library cache during execute: 1 Optimizer mode: CHOOSE Parsing user id: SYS (recursive depth: 1).Msg 8928, Level 16, State 2, Line 1 Object ID 1709768623, index ID 1, partition ID 72057606886326272, alloc unit ID 72057606897008640 (type In-row data): Page (1:2240107) could not be processed.Yes, i just realised my remove method always assumed that only the currentSelectedItem will be removed.

Recovering orphaned file AsusSetup.exe (87) into directory file 84.If the costs of two queries (now I compare queries doing really different things) are different by orders of magnitude (I used 50 and 123456 in my example), then yes, the second query is most probably slower than the first one.

TKPROF: Release 10.2.0.1.0 - Production on Tue Mar 29 15:25:43 2011.The off-row data node at page (1:404355), slot 2, text ID 97656307712 is referenced by page (1:355153), slot 6, but was not seen in the scan.

Its a system generated query but I need to improve its performance.The off-row data node at page (1:404357), slot 3, text ID 97656766464 is referenced by page (1:404178), slot 149, but was not seen in the scan.Page (1:2324) was not seen in the scan although its parent (1:2037) and previous (1:2039) refer to it.Msg 8909, Level 16, State 1, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 0 (type Unknown), page ID (1:404351) contains an incorrect page ID in its page header.Recovering orphaned file ahcix64s.inf (452) into directory file 450.The off-row data node at page (1:404346), slot 0, text ID 97652834304 is referenced by page (1:404315), slot 11, but was not seen in the scan.Recovering orphaned file Folder.jpg (9360) into directory file 4811.Also note the usage of the code tag when posting on the forum for formatting things like execution plans, tkprof, etc.The text, ntext, or image node at page (1:683), slot 0, text ID 33685504 is not referenced.

At the top-right hand corner of the window, click the button with three dots on it, then Settings.DB:3.42:Re: Query Executing View Based Function Is Slow From App But Ok From Sqlplu 97.If the object is an ActiveX or Flash object, you may need to use Windows Event Recorder.Misses in library cache during parse: 1 Optimizer mode: CHOOSE Parsing user id: 158 (SYSMANDEV).Loc-Line 1/2 inch Flat Slot 125 Nozzle ← Previous product. Next product →.The off-row data node at page (1:404355), slot 0, text ID 97656045568 is referenced by page (1:346884), slot 11, but was not seen in the scan.Msg 8909, Level 16, State 1, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 0 (type Unknown), page ID (1:404345) contains an incorrect page ID in its page header.

From my efforts I decovered that the certesian join in the explain plan is the major cause of the slowness and removing the join by rewriting the application is the headache because that may job flow of the application.Values are 0 and 8192.::. The system cannot self repair this error.Msg 8939, Level 16, State 98, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 7258917288141062144 (type Unknown), page (2550:238301252).The 10g plan had some partition selects that I did not see in the 11g plan.